Eppendorf 5810 R Centrifuge User Manual

Browse online or download User Manual for Equipment Eppendorf 5810 R Centrifuge. Eppendorf 5810 R Centrifuge User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 95
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Centrifuge 5804/5804 R/5810/5810 R
Operating manual
5820 900.040
Page view 0
1 2 3 4 5 6 ... 94 95

Summary of Contents

Page 1 - Operating manual

Centrifuge 5804/5804 R/5810/5810 ROperating manual 5820 900.040

Page 2

Centrifuge 5804/5804 R/5810/5810 R — Operating manual10 1.4 Abbreviations usedMTP Micro test plateNN Mean sea level (MSL)PCR Polymerase chain reacti

Page 3 -  Press +

11Centrifuge 5804/5804 R/5810/5810 R — Operating manual 2 Product description2 Product description2.1 Main illustrationAbb. 1: Depiction of Centrifu

Page 4

Centrifuge 5804/5804 R/5810/5810 R — Operating manual12 Only 5804R and 5810R:2.3 FeaturesThe versatile 5804/5804R/5810/5810R centrifuge has a ca

Page 5

13Centrifuge 5804/5804 R/5810/5810 R — Operating manual 2.4 RotorsYou can operate the 5804/5804R/5810/5810R centrifuge with the following rotors.

Page 6

Centrifuge 5804/5804 R/5810/5810 R — Operating manual14 Blood collection tube5810 748.003flat 3,000 × g3 to 15mL Ø 16mm 4,000rpm16/64 108mm/108

Page 7

15Centrifuge 5804/5804 R/5810/5810 R — Operating manual Rotor A-4-81 with conical tubesWide-neck bottle, rectangular- flat 3,220×g500mL 83 mm 4,0

Page 8

Centrifuge 5804/5804 R/5810/5810 R — Operating manual16 Rotor A-4-81 with MTP/Flex carrierMax. g-force: 2,900×gRotor A-4-81 MTP/Flex buckets Max.

Page 9

17Centrifuge 5804/5804 R/5810/5810 R — Operating manual Slides CombiSlide5825 706.005flat 1,000×g12slides - 2,372rpm12/48 60mm 15.9 cmCell cult

Page 10

Centrifuge 5804/5804 R/5810/5810 R — Operating manual18 2.4.2 Rotor A-4-62 and A-4-62-MTP (only 5810/5810 R)Rotor A-4-62 with 250 mL rectangular buc

Page 11

19Centrifuge 5804/5804 R/5810/5810 R — Operating manual Vessel5810 756.006flat 3,050×g7 to 18mL Ø 20mm 4,000rpm8/32 119mm/126mm 17.3 cmVessel

Page 12

5820 900.040-02/122012 Copyright © 2012 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copy

Page 13

Centrifuge 5804/5804 R/5810/5810 R — Operating manual20 Rotor A-4-62 with MTP carrierBottles5810 770.009flat 3,220×g180 to 250mL Ø 62mm 4,000rp

Page 14

21Centrifuge 5804/5804 R/5810/5810 R — Operating manual 96-well PCR plate 5825 711.009flat 2,600×g4,000rpm1/4 53mm 15.2 cmSlides CombiSlide5825

Page 15

Centrifuge 5804/5804 R/5810/5810 R — Operating manual22 2.4.3 Rotor A-4-44Max. g-force: 4,400×gRotor A-4-44 Rectangular bucket 100mLAerosol-tight

Page 16

23Centrifuge 5804/5804 R/5810/5810 R — Operating manual Conical tube5804 717.007conical 4,400×g15mL Ø 17.5mm 5,000rpm2/8 121mm/121mm 15.7 cmV

Page 17

Centrifuge 5804/5804 R/5810/5810 R — Operating manual24 2.4.4 Rotor A-2-DWP-AT (only 5810/5810 R)Vessel5804 760.000flat 4,200×g50 to 75mL Ø 35mm

Page 18

25Centrifuge 5804/5804 R/5810/5810 R — Operating manual Kit - 3,486×g4,500rpm1/4 60 mm 154 mmIsoRack open 2,500×g24×0.5mL micro test tubesØ

Page 19

Centrifuge 5804/5804 R/5810/5810 R — Operating manual26 2.4.5 Rotor A-2-DWPHint!Check the load if using two fully loaded DWP plates.Max. g-force: 2,

Page 20

27Centrifuge 5804/5804 R/5810/5810 R — Operating manual *) Optional. Secures the plate against slipping .384-well PCR plate5825 713.001flat 2,170×

Page 21

Centrifuge 5804/5804 R/5810/5810 R — Operating manual28 2.4.6 Rotor FA-45-6-30Rotor FA-45-6-30Fixed-angle rotor for 6conical tubesMax. g-force: 16,

Page 22

29Centrifuge 5804/5804 R/5810/5810 R — Operating manual 2.4.7 Rotor F-34-6-38Vessel5820 728.000Round 16,233×g 5.5mL – 10mL Ø 16mm 19,246 ×g1/6

Page 23

You will find a detailed description of these figures in your language in Chapters 2.1 and 5.1.Abb. 1: Depiction of Centrifuge 5810 and 5810R. The Ce

Page 24

Centrifuge 5804/5804 R/5810/5810 R — Operating manual30 Blood collection tube5804 739.000Round 15,442×g4 mL to 7mL Ø 13mm 18,353×g3/18 107mm

Page 25

31Centrifuge 5804/5804 R/5810/5810 R — Operating manual 2.4.8 Rotors FA-45-30-11 and F-45-30-11Rotor FA-45-30-11Aerosol-tight fixed-angle rotor for

Page 26

Centrifuge 5804/5804 R/5810/5810 R — Operating manual32 2.4.9 Rotor F-45-48-PCR2.4.10 Rotor T-60-11Rotor F-45-48-PCRFixed-angle rotor for tube strip

Page 27

33Centrifuge 5804/5804 R/5810/5810 R — Operating manual 2.4.11 Rotor S-4-104 (only 5810/5810 R)Max. g-force: 3,214×gRotor S-4-104 Round bucket 750

Page 28

Centrifuge 5804/5804 R/5810/5810 R — Operating manual34 Conical tube5825 733.002conical 3,180×g50mL Ø 29mm× 109mm 3,900rpm7/28 116mm/122mm

Page 29

35Centrifuge 5804/5804 R/5810/5810 R — Operating manual Max. g-force: 2,568×gRotor S-4-104 Plate bucket Aerosol-tight cap Max. speed: 3,900rpmSwi

Page 30

Centrifuge 5804/5804 R/5810/5810 R — Operating manual36 2.4.12 Rotor S-4-72Slides CombiSlide5825 706.005flat 1,000×g12slides 2.467rpm12/48 47mm

Page 31

37Centrifuge 5804/5804 R/5810/5810 R — Operating manual Conical tube5804 783.000conical 3,234×g15mL Ø 17mm × 104mm 4,200rpm8/32 120 mm 16.4 cm

Page 32

Centrifuge 5804/5804 R/5810/5810 R — Operating manual38 2.4.13 Rotor F-35-48-17Max. g-force: 5,005 ×gRotor F-35-48-17 Max. speed: 5,500rpmFixed-an

Page 33

39Centrifuge 5804/5804 R/5810/5810 R — Operating manual 2.4.14 Rotor FA-45-48-11Max. g-force: 19,083 ×gRotor FA-45-48-11 Max. speed: 13,000rpmAero

Page 34

Abb. 2: Control panel of the Centrifuge 5804/5810 and theCentrifuge 5804R/5810R.Control panel of the Centrifuge 5804/5810 and theCentrifuge 5804R/5

Page 35

Centrifuge 5804/5804 R/5810/5810 R — Operating manual40 2.4.15 Rotor FA-45-20-17Max. g-force: 20,913 ×gRotor FA-45-20-17 Max. speed: 13,100rpmAero

Page 36

41Centrifuge 5804/5804 R/5810/5810 R — Operating manual 3 Safety3 Safety3.1 Intended useThe 5804/5804R/5810/5810R centrifuge is intended exclusive

Page 37

Centrifuge 5804/5804 R/5810/5810 R — Operating manual42 For all other rotors and rotor lids of this centrifuge there is no service life limit as lon

Page 38

43Centrifuge 5804/5804 R/5810/5810 R — Operating manual 3.5 Warnings for intended useRead the operating manual and observe the following general saf

Page 39

Centrifuge 5804/5804 R/5810/5810 R — Operating manual44 3.5.2 Incorrect handling of the centrifugeWARNING!A defective gas spring is an insufficient

Page 40

45Centrifuge 5804/5804 R/5810/5810 R — Operating manual 3.5.3 Incorrect handling of the rotorsWARNING!Risk of injury from improperly attached rotors

Page 41

Centrifuge 5804/5804 R/5810/5810 R — Operating manual46 3.5.4 Extreme strain on the centrifuging tubesCAUTION!Risk of injury from overloaded tubes.

Page 42

47Centrifuge 5804/5804 R/5810/5810 R — Operating manual 3.5.5 Aerosol-tight centrifugation3.6 Safety instructions located on the deviceWARNING!Risk

Page 43

Centrifuge 5804/5804 R/5810/5810 R — Operating manual48 4 Installation4 Installation4.1 Selecting the locationSelect the location for the device acc

Page 44

49Centrifuge 5804/5804 R/5810/5810 R — Operating manual 4.3 Installing the instrumentPerform the following steps in the sequence described.1. Allow

Page 45

5Centrifuge 5804/5804 R/5810/5810 R — Operating manual Operating manual — Centrifuge 5804/5804 R/5810/5810 Rseeon p.Fig.Tab.p.Operating manual1 T

Page 46

Centrifuge 5804/5804 R/5810/5810 R — Operating manual50 5 Operation5 Operation5.1 Overview of operating controlsBefore using the centrifuge for the

Page 47

51Centrifuge 5804/5804 R/5810/5810 R — Operating manual 5.2 Preparing for centrifugation5.2.1 Switching on the centrifuge1. Switch on the centrifuge

Page 48

Centrifuge 5804/5804 R/5810/5810 R — Operating manual52 5.2.4 Loading the rotorFixed-angle rotorsTo load the rotor, proceed as follows:1. Check the

Page 49

53Centrifuge 5804/5804 R/5810/5810 R — Operating manual Swing-bucket rotorPrerequisites• A combination of rotor, carrier and adapter, approved by Ep

Page 50

Centrifuge 5804/5804 R/5810/5810 R — Operating manual54 Abb. 5: Loading the adapter 16mm75 - 100mm with tubes >119mm in length.Fig. 5: Loadi

Page 51

55Centrifuge 5804/5804 R/5810/5810 R — Operating manual 5.2.5 Closing the centrifuge lid1. Check the correct attachment of the rotor and rotor lid.2

Page 52

Centrifuge 5804/5804 R/5810/5810 R — Operating manual56 temperature, 4°C must be met via this continuous cooling in order to prevent the rotor cha

Page 53

57Centrifuge 5804/5804 R/5810/5810 R — Operating manual 5.4 CentrifugingEach of the centrifuging variants described here must be preceded by the pre

Page 54

Centrifuge 5804/5804 R/5810/5810 R — Operating manual58 5.4.2 Centrifuging in continuous operationPerform the following steps in the sequence descri

Page 55

59Centrifuge 5804/5804 R/5810/5810 R — Operating manual 5.4.4 Removing the rotorPrerequisitesWhen attaching the rotor to or releasing it from the mo

Page 56

Centrifuge 5804/5804 R/5810/5810 R — Operating manual6 5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 57

Centrifuge 5804/5804 R/5810/5810 R — Operating manual60 6 Operating controls and function6 Operating controls and function6.1 Setting the radiusWhen

Page 58

61Centrifuge 5804/5804 R/5810/5810 R — Operating manual 6.4 Saving the programYou can save the current centrifugation parameters and functions (At s

Page 59

Centrifuge 5804/5804 R/5810/5810 R — Operating manual62 6.7 Special functions6.7.1 Display operating hoursRequirementRotor stop.6.7.2 Switching on/o

Page 60

63Centrifuge 5804/5804 R/5810/5810 R — Operating manual 7 Maintenance7 Maintenance7.1 MaintenanceWe recommend that the centrifuge with the associate

Page 61

Centrifuge 5804/5804 R/5810/5810 R — Operating manual64 7.3 Cleaning/disinfectionDANGER!Electric shock as a result of penetration of liquid. Switch

Page 62

65Centrifuge 5804/5804 R/5810/5810 R — Operating manual 7.3.1 Cleaning and disinfecting the device1. Open the lid. Switch off the device with the ma

Page 63

Centrifuge 5804/5804 R/5810/5810 R — Operating manual66 7.4 Additional service instructions for Centrifuge 5804R/5810R Empty and clean the conden

Page 64

67Centrifuge 5804/5804 R/5810/5810 R — Operating manual 8 Troubleshooting8 TroubleshootingIf you cannot remedy an error with the recommended measure

Page 65

Centrifuge 5804/5804 R/5810/5810 R — Operating manual68 No rotorCentrifuge does not start up.Error in the drive or in the rotor detection. Switch t

Page 66

69Centrifuge 5804/5804 R/5810/5810 R — Operating manual 8.4 Emergency releaseIf the centrifuge lid cannot be opened, you can activate the emergency

Page 67

7Centrifuge 5804/5804 R/5810/5810 R — Operating manual 10 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 68

Centrifuge 5804/5804 R/5810/5810 R — Operating manual70 9 Transport, storage and disposal9 Transport, storage and disposal9.1 Transport Remove the

Page 69

71Centrifuge 5804/5804 R/5810/5810 R — Operating manual 10 Technical data10 Technical data10.1 Power supply10.2 Ambient conditions10.3 Weight/dimens

Page 70

Centrifuge 5804/5804 R/5810/5810 R — Operating manual72 The noise level was measured according to DIN EN ISO 3745 frontally in a sound measuring roo

Page 71

73Centrifuge 5804/5804 R/5810/5810 R — Operating manual Deceleration times according to DIN 58 970Tab. 2: Approximate deceleration times of the dif

Page 72

Centrifuge 5804/5804 R/5810/5810 R — Operating manual74 11 Ordering information11 Ordering information11.1 Centrifuge 5804/5804 RPlease refer to our

Page 73

75Centrifuge 5804/5804 R/5810/5810 R — Operating manual Rotor A-4-81, MTP/Flex carrier5810 745.0045810 746.0005810 720.0015825 717.0075810 748.00358

Page 74

Centrifuge 5804/5804 R/5810/5810 R — Operating manual76 Rotor A-4-81, bucket for conical tubes11.3.2 Rotor A-4-62 and A-4-62-MTP (only 5810/5810 R)R

Page 75

77Centrifuge 5804/5804 R/5810/5810 R — Operating manual Rotor A-4-62-MTP11.3.3 Rotor A-4-445810 781.000 022662431Replacement clampfor adapters for 2

Page 76

Centrifuge 5804/5804 R/5810/5810 R — Operating manual78 11.3.4 Rotor A-2-DWP-AT (only 5810/5810 R)Aerosol impermeability tested and certified by the

Page 77

79Centrifuge 5804/5804 R/5810/5810 R — Operating manual 11.3.6 Rotor FA-45-6-30Aerosol impermeability tested and certified by the Centre of Emergenc

Page 78

Centrifuge 5804/5804 R/5810/5810 R — Operating manual8 ENOperating manual

Page 79

Centrifuge 5804/5804 R/5810/5810 R — Operating manual80 11.3.8 Rotor FA-45-30-11 and rotor F-45-30-1111.3.9 Rotor F-45-48-PCR11.3.10 Rotor T-60-1158

Page 80

81Centrifuge 5804/5804 R/5810/5810 R — Operating manual 11.3.11 Rotor S-4-104Order no. (international)Order No. (North America)Description5820 740.0

Page 81

Centrifuge 5804/5804 R/5810/5810 R — Operating manual82 11.3.12 Rotor S-4-7211.3.13 Rotor F-35-48-1711.3.14 FA-45-48-11 rotor5820 751.002 5820751002

Page 82

83Centrifuge 5804/5804 R/5810/5810 R — Operating manual 11.3.15 Rotor FA-45-20-1711.3.16 Miscellaneous5820 767.006 5820767006Seal for rotor lidFA-45

Page 83

Centrifuge 5804/5804 R/5810/5810 R — Operating manual84 Power cable for Centrifuge 5804 and Centrifuge 5810Power cable for Centrifuge 5804 R and Cen

Page 89

9Centrifuge 5804/5804 R/5810/5810 R — Operating manual 1 User instructions1 User instructions1.1 Using this manual Read this operating manual compl

Page 95

Your local distributor: www.eppendorf.com/worldwideEppendorf AG · 22331 Hamburg · Germany · Tel: +49 40 53801-0 · Fax: +49 40 538 01-556 · E-mail: epp

Comments to this Manuals

No comments